DUO Series Select a model for full specifications
Select a model for full specifications
|
DUO 60
|
100
|
20
|
39
|
35
|
6
|
DUO 60
|
Product Details – DUO 60
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)39
- Noise Level (dBA @ 1m.)35
- Weight (kg)6
Features
- Dual outlet ports with integrated cam-style valves and programmable timer controller to alternate between two aeration processes
- Available with integral low-pressure alarms.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Equipped with thermal overload protection
- Includes pressure tap location for external alarm sensor
|
DUO 80
|
110
|
25
|
58
|
35
|
6
|
DUO 80
|
Product Details – DUO 80
- Max Flow (lpm)110
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)58
- Noise Level (dBA @ 1m.)35
- Weight (kg)6
Features
- Dual outlet ports with integrated cam-style valves and programmable timer controller to alternate between two aeration processes
- Available with integral low-pressure alarms.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Equipped with thermal overload protection
- Includes pressure tap location for external alarm sensor
|
HP Alarm Units Select a model for full specifications
Select a model for full specifications
|
HP-40A
|
60
|
20
|
38
|
32
|
6.1
|
HP-40A
|
Product Details – HP-40A
- Max Flow (lpm)60
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)38
- Noise Level (dBA @ 1m.)32
- Weight (kg)6.1
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-60A
|
100
|
25
|
51
|
35
|
7.4
|
HP-60A
|
Product Details – HP-60A
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)51
- Noise Level (dBA @ 1m.)35
- Weight (kg)7.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-80A
|
120
|
25
|
71
|
39
|
7.4
|
HP-80A
|
Product Details – HP-80A
- Max Flow (lpm)120
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)71
- Noise Level (dBA @ 1m.)39
- Weight (kg)7.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100A
|
110
|
25
|
100
|
38
|
8.9
|
HP-100A
|
Product Details – HP-100A
- Max Flow (lpm)110
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)38
- Weight (kg)8.9
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100LLA
|
130
|
30
|
75
|
42
|
9.4
|
HP-100LLA
|
Product Details – HP-100LLA
- Max Flow (lpm)130
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)75
- Noise Level (dBA @ 1m.)42
- Weight (kg)9.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-120LLA
|
150
|
30
|
100
|
42
|
9.4
|
HP-120LLA
|
Product Details – HP-120LLA
- Max Flow (lpm)150
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)42
- Weight (kg)9.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-120A
|
150
|
25
|
125
|
40
|
8.9
|
HP-120A
|
Product Details – HP-120A
- Max Flow (lpm)150
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)125
- Noise Level (dBA @ 1m.)40
- Weight (kg)8.9
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-150A
|
200
|
30
|
155
|
47
|
9
|
HP-150A
|
Product Details – HP-150A
- Max Flow (lpm)200
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)155
- Noise Level (dBA @ 1m.)47
- Weight (kg)9
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-200A
|
200
|
30
|
250
|
48
|
9
|
HP-200A
|
Product Details – HP-200A
- Max Flow (lpm)200
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)250
- Noise Level (dBA @ 1m.)48
- Weight (kg)9
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-Series Select a model for full specifications
Select a model for full specifications
|
HP-20
|
32
|
15
|
17
|
32
|
3.2
|
HP-20
|
Product Details – HP-20
- Max Flow (lpm)32
- Max Cont Operating Pressure (kPa)15
- Power Consumption (Watts)17
- Noise Level (dBA @ 1m.)32
- Weight (kg)3.2
Features
- Standard model available only for 120VAC applications.
- Pumps equipped with thermal overload protection.
|
HP-40
|
80
|
20
|
38
|
32
|
5.7
|
HP-40
|
Product Details – HP-40
- Max Flow (lpm)80
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)38
- Noise Level (dBA @ 1m.)32
- Weight (kg)5.7
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-60
|
100
|
25
|
51
|
35
|
7
|
HP-60
|
Product Details – HP-60
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)51
- Noise Level (dBA @ 1m.)35
- Weight (kg)7
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-80
|
120
|
25
|
71
|
36
|
7
|
HP-80
|
Product Details – HP-80
- Max Flow (lpm)120
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)71
- Noise Level (dBA @ 1m.)36
- Weight (kg)7
Features
- Available with low pressure alarms for 120VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Dual port models available with internal flow switching solenoids and programmable timers for aerator/skimmer applications.
- Contact us for custom voltage applications, including 24 – 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100
|
110
|
25
|
100
|
38
|
8.5
|
HP-100
|
Product Details – HP-100
- Max Flow (lpm)110
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)38
- Weight (kg)8.5
Features
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100LL
|
130
|
30
|
75
|
42
|
9
|
HP-100LL
|
Product Details – HP-100LL
- Max Flow (lpm)130
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)75
- Noise Level (dBA @ 1m.)42
- Weight (kg)9
Features
- Available with low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-120
|
150
|
25
|
125
|
40
|
8.5
|
HP-120
|
Product Details – HP-120
- Max Flow (lpm)150
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)125
- Noise Level (dBA @ 1m.)40
- Weight (kg)8.5
Features
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-120LL
|
150
|
30
|
100
|
45
|
9
|
HP-120LL
|
Product Details – HP-120LL
- Max Flow (lpm)150
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)45
- Weight (kg)9
Features
- Available with low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-150
|
200
|
30
|
155
|
47
|
9
|
HP-150
|
Product Details – HP-150
- Max Flow (lpm)200
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)155
- Noise Level (dBA @ 1m.)47
- Weight (kg)9
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-200
|
240
|
30
|
250
|
48
|
9
|
HP-200
|
Product Details – HP-200
- Max Flow (lpm)240
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)250
- Noise Level (dBA @ 1m.)48
- Weight (kg)9
Features
- Available with integral low-pressure alarms for 120VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
XP Alarm Series Select a model for full specifications
Select a model for full specifications
|
XP-40A
|
70
|
20
|
24
|
30
|
4.1
|
XP-40A
|
Product Details – XP-40A
- Max Flow (lpm)70
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)24
- Noise Level (dBA @ 1m.)30
- Weight (kg)4.1
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
XP-60A
|
90
|
23
|
40
|
35
|
4.3
|
XP-60A
|
Product Details – XP-60A
- Max Flow (lpm)90
- Max Cont Operating Pressure (kPa)23
- Power Consumption (Watts)40
- Noise Level (dBA @ 1m.)35
- Weight (kg)4.3
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
XP-80A
|
100
|
27
|
64
|
35
|
4.3
|
XP-80A
|
Product Details – XP-80A
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)27
- Power Consumption (Watts)64
- Noise Level (dBA @ 1m.)35
- Weight (kg)4.3
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
XP Series Select a model for full specifications
Select a model for full specifications
|
XP-40
|
70
|
20
|
24
|
30
|
4.1
|
XP-40
|
Product Details – XP-40
- Max Flow (lpm)70
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)24
- Noise Level (dBA @ 1m.)30
- Weight (kg)4.1
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
XP-60
|
90
|
23
|
40
|
35
|
4.3
|
XP-60
|
Product Details – XP-60
- Max Flow (lpm)90
- Max Cont Operating Pressure (kPa)23
- Power Consumption (Watts)40
- Noise Level (dBA @ 1m.)35
- Weight (kg)4.3
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
XP-80
|
100
|
27
|
64
|
35
|
4.3
|
XP-80
|
Product Details – XP-80
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)27
- Power Consumption (Watts)64
- Noise Level (dBA @ 1m.)35
- Weight (kg)4.3
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|