We have manufactured air pumps for a wide variety of industrial applications for over 30 years. We know that precision, safety, and reliability are paramount for the components utilized in your products and systems. We have experience working with OEM’s in gas detection, packaging, air filtration, automation systems, and many other functions and usages. Whether your system or device requires vacuum or pressure, HIBLOW can provide a pneumatic solution that fits your specific requirements.


Adaptable and Efficient

From 5V through 230V, 50hz or 60hz, we can tailor a linear pump to fit your electrical needs. The power consumption of our entire product line is extremely efficient, with the majority of our industrial pumps consuming approximately the same energy as a standard LED light bulb.

Reliable Linear Design

HIBLOW’s linear pump technology is oil and lubrication free, so there is no worry of contamination. Since 1972, HIBLOW pumps have been built upon the pillars of precision manufacturing and innovative engineering. HIBLOW invented the linear pump technology that powers our units still today. Our linear diaphragm pump design allows for a quick and inexpensive repair, by simply installing a new set of diaphragms.

Watch a demonstration of how our linear pump works »

Tailored Manufacturing

Our business is built upon OEM relationships—many of those partnerships are measured in decades. With technology changing by the day, we are proud of our long-term commitments to grow and adapt with our customers.

We have the experience and capacity for large production volumes, while retaining the flexibility of a custom manufacturer.

Airtronics

Our Airtronics team continues to develop valve and controller technology that allows one HIBLOW air pump to serve multiple functions within an overall system. Our engineering team can assist with you with integrating these functions into your system and controls.

Please contact us for pricing and availability of pumps, or to arrange for an evaluation unit for testing.

Industrial Pumps for All Applications

C-Series Select a model for full specifications

Product Details – C-5BN

  • Max Flow (lpm)10
  • Max Cont Operating Pressure (kPa)20
  • Power Consumption (Watts)8.5
  • Noise Level (dBA @ 1m.)34
  • Weight (kg).7

Features

  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including DC system applications using external PWM controllers for modulating pump flow.

Product Details – CD-8

  • Max Flow (lpm)17
  • Max Cont Operating Pressure (kPa)20
  • Power Consumption (Watts)8.5
  • Noise Level (dBA @ 1m.)34
  • Weight (kg).7

Features

  • Our CD-8 is a C-5BN chassis with enhanced internal sealing for applications requiring improved pneumatic isolation from ambient contamination and the pump’s energized components.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including DC system applications using external PWM controllers for modulating pump flow.

HP-Series Select a model for full specifications

Product Details – HP-20

  • Max Flow (lpm)32
  • Max Cont Operating Pressure (kPa)15
  • Power Consumption (Watts)17
  • Noise Level (dBA @ 1m.)32
  • Weight (kg)3.2

Features

  • Standard model available only for 120VAC applications.
  • Pumps equipped with thermal overload protection.

Product Details – HP-40

  • Max Flow (lpm)80
  • Max Cont Operating Pressure (kPa)20
  • Power Consumption (Watts)38
  • Noise Level (dBA @ 1m.)32
  • Weight (kg)5.7

Features

  • Available with integral low-pressure alarms for 120 VAC applications.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
  • Includes pressure tap location for external alarm sensor

Product Details – HP-60

  • Max Flow (lpm)100
  • Max Cont Operating Pressure (kPa)25
  • Power Consumption (Watts)51
  • Noise Level (dBA @ 1m.)35
  • Weight (kg)7

Features

  • Available with integral low-pressure alarms for 120 VAC applications.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
  • Includes pressure tap location for external alarm sensor

Product Details – HP-80

  • Max Flow (lpm)120
  • Max Cont Operating Pressure (kPa)25
  • Power Consumption (Watts)71
  • Noise Level (dBA @ 1m.)36
  • Weight (kg)7

Features

  • Available with low pressure alarms for 120VAC applications.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Dual port models available with internal flow switching solenoids and programmable timers for aerator/skimmer applications.
  • Contact us for custom voltage applications, including 24 – 48 VDC system applications using external PWM controllers for modulating pump flow.

Product Details – HP-100

  • Max Flow (lpm)110
  • Max Cont Operating Pressure (kPa)25
  • Power Consumption (Watts)100
  • Noise Level (dBA @ 1m.)38
  • Weight (kg)8.5

Features

  • Standard UL approved 120 VAC models
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.

Product Details – HP-100LL

  • Max Flow (lpm)130
  • Max Cont Operating Pressure (kPa)30
  • Power Consumption (Watts)75
  • Noise Level (dBA @ 1m.)42
  • Weight (kg)9

Features

  • Available with low-pressure alarms for 120 VAC applications.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
  • Includes pressure tap location for external alarm sensor

Product Details – HP-120

  • Max Flow (lpm)150
  • Max Cont Operating Pressure (kPa)25
  • Power Consumption (Watts)125
  • Noise Level (dBA @ 1m.)40
  • Weight (kg)8.5

Features

  • Standard UL approved 120 VAC models
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.

Product Details – HP-120LL

  • Max Flow (lpm)150
  • Max Cont Operating Pressure (kPa)30
  • Power Consumption (Watts)100
  • Noise Level (dBA @ 1m.)45
  • Weight (kg)9

Features

  • Available with low-pressure alarms for 120 VAC applications.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
  • Includes pressure tap location for external alarm sensor

Product Details – HP-150

  • Max Flow (lpm)200
  • Max Cont Operating Pressure (kPa)30
  • Power Consumption (Watts)155
  • Noise Level (dBA @ 1m.)47
  • Weight (kg)9

Features

  • Available with integral low-pressure alarms for 120 VAC applications.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
  • Includes pressure tap location for external alarm sensor

Product Details – HP-200

  • Max Flow (lpm)240
  • Max Cont Operating Pressure (kPa)30
  • Power Consumption (Watts)250
  • Noise Level (dBA @ 1m.)48
  • Weight (kg)9

Features

  • Available with integral low-pressure alarms for 120VAC applications.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
  • Includes pressure tap location for external alarm sensor

KP (S) Series Select a model for full specifications

Product Details – KP-4020S

  • Max Flow (lpm)
  • Max Cont Operating Pressure (kPa)
  • Power Consumption (Watts)
  • Noise Level (dBA @ 1m.)
  • Weight (kg)

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Energized component isolation from pumped fluid for “S” models.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

Product Details – KP-5030S

  • Max Flow (lpm)
  • Max Cont Operating Pressure (kPa)
  • Power Consumption (Watts)
  • Noise Level (dBA @ 1m.)
  • Weight (kg)

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Energized component isolation from pumped fluid for “S” models.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

Product Details – KP-6035S

  • Max Flow (lpm)
  • Max Cont Operating Pressure (kPa)
  • Power Consumption (Watts)
  • Noise Level (dBA @ 1m.)
  • Weight (kg)

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Energized component isolation from pumped fluid for “S” models.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

KP-Series Select a model for full specifications

Product Details – KP-4020

  • Max Flow (lpm)37
  • Max Cont Operating Pressure (kPa)27
  • Power Consumption (Watts)18
  • Noise Level (dBA @ 1m.)31
  • Weight (kg)3.8

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

Product Details – KP-5030

  • Max Flow (lpm)42
  • Max Cont Operating Pressure (kPa)33
  • Power Consumption (Watts)27
  • Noise Level (dBA @ 1m.)34
  • Weight (kg)3.8

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

Product Details – KP-6035

  • Max Flow (lpm)51
  • Max Cont Operating Pressure (kPa)38
  • Power Consumption (Watts)35
  • Noise Level (dBA @ 1m.)36
  • Weight (kg)3.8

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

NS-Series Select a model for full specifications

Product Details – NS-30

  • Max Flow (lpm)45
  • Max Cont Operating Pressure (kPa)8
  • Power Consumption (Watts)12
  • Noise Level (dBA @ 1m.)45
  • Weight (kg)1.2

Features

  • Quiet and light weight
  • Standard UL listed models available for 120 and 230 VAC.
  • Pumps equipped with thermal overload protection.

VP (S) Series Select a model for full specifications

Product Details – VP-4020S

  • Max Flow (lpm)
  • Max Cont Operating Pressure (kPa)
  • Power Consumption (Watts)
  • Noise Level (dBA @ 1m.)
  • Weight (kg)

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Energized component isolation from pumped fluid for “S” models.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

Product Details – VP-5030S

  • Max Flow (lpm)
  • Max Cont Operating Pressure (kPa)
  • Power Consumption (Watts)
  • Noise Level (dBA @ 1m.)
  • Weight (kg)

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Energized component isolation from pumped fluid for “S” models.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

Product Details – VP-6035S

  • Max Flow (lpm)
  • Max Cont Operating Pressure (kPa)
  • Power Consumption (Watts)
  • Noise Level (dBA @ 1m.)
  • Weight (kg)

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Energized component isolation from pumped fluid for “S” models.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

Product Details – VP-7045S

  • Max Flow (lpm)
  • Max Cont Operating Pressure (kPa)
  • Power Consumption (Watts)
  • Noise Level (dBA @ 1m.)
  • Weight (kg)

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Energized component isolation from pumped fluid for “S” models.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

VP-Series Select a model for full specifications

Product Details – VP-4020

  • Max Flow (lpm)42
  • Max Cont Operating Pressure (kPa)26
  • Power Consumption (Watts)18
  • Noise Level (dBA @ 1m.)43
  • Weight (kg)1.95

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

Product Details – VP-5030

  • Max Flow (lpm)54
  • Max Cont Operating Pressure (kPa)32
  • Power Consumption (Watts)27
  • Noise Level (dBA @ 1m.)44
  • Weight (kg)1.95

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

Product Details – VP-6035

  • Max Flow (lpm)60
  • Max Cont Operating Pressure (kPa)38
  • Power Consumption (Watts)35
  • Noise Level (dBA @ 1m.)45
  • Weight (kg)1.95

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

Product Details – VP-7045

  • Max Flow (lpm)62
  • Max Cont Operating Pressure (kPa)25
  • Power Consumption (Watts)41
  • Noise Level (dBA @ 1m.)46
  • Weight (kg)1.95

Features

  • Optional port locations for maximum design flexibility.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.

XP Series Select a model for full specifications

Product Details – XP-40

  • Max Flow (lpm)70
  • Max Cont Operating Pressure (kPa)20
  • Power Consumption (Watts)24
  • Noise Level (dBA @ 1m.)30
  • Weight (kg)4.1

Features

  • Available with integral low-pressure alarms for 120 VAC applications.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
  • Includes pressure tap location for external alarm sensor

Product Details – XP-60

  • Max Flow (lpm)90
  • Max Cont Operating Pressure (kPa)23
  • Power Consumption (Watts)40
  • Noise Level (dBA @ 1m.)35
  • Weight (kg)4.3

Features

  • Available with integral low-pressure alarms for 120 VAC applications.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
  • Includes pressure tap location for external alarm sensor

Product Details – XP-80

  • Max Flow (lpm)100
  • Max Cont Operating Pressure (kPa)27
  • Power Consumption (Watts)64
  • Noise Level (dBA @ 1m.)35
  • Weight (kg)4.3

Features

  • Available with integral low-pressure alarms for 120 VAC applications.
  • Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
  • Pumps equipped with thermal overload protection.
  • Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
  • Includes pressure tap location for external alarm sensor
(734) 944-5032 Call info@HIBLOW-USA.com Email Contact Us! Contact