C-Series Select a model for full specifications
Select a model for full specifications
|
C-5BN
|
10
|
20
|
8.5
|
34
|
.7
|
C-5BN
|
Product Details – C-5BN
- Max Flow (lpm)10
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)8.5
- Noise Level (dBA @ 1m.)34
- Weight (kg).7
Features
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including DC system applications using external PWM controllers for modulating pump flow.
|
CD-8
|
17
|
20
|
8.5
|
34
|
.7
|
CD-8
|
Product Details – CD-8
- Max Flow (lpm)17
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)8.5
- Noise Level (dBA @ 1m.)34
- Weight (kg).7
Features
- Our CD-8 is a C-5BN chassis with enhanced internal sealing for applications requiring improved pneumatic isolation from ambient contamination and the pump’s energized components.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including DC system applications using external PWM controllers for modulating pump flow.
|
DUO Series Select a model for full specifications
Select a model for full specifications
|
DUO 60
|
100
|
20
|
39
|
35
|
6
|
DUO 60
|
Product Details – DUO 60
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)39
- Noise Level (dBA @ 1m.)35
- Weight (kg)6
Features
- Dual outlet ports with integrated cam-style valves and programmable timer controller to alternate between two aeration processes
- Available with integral low-pressure alarms.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Equipped with thermal overload protection
- Includes pressure tap location for external alarm sensor
|
DUO 80
|
110
|
25
|
58
|
35
|
6
|
DUO 80
|
Product Details – DUO 80
- Max Flow (lpm)110
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)58
- Noise Level (dBA @ 1m.)35
- Weight (kg)6
Features
- Dual outlet ports with integrated cam-style valves and programmable timer controller to alternate between two aeration processes
- Available with integral low-pressure alarms.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Equipped with thermal overload protection
- Includes pressure tap location for external alarm sensor
|
FC Series for Hydrogen Fuel Cells Select a model for full specifications
Select a model for full specifications
|
FC-0220
|
1.5
|
20
|
3
|
25
|
.8
|
FC-0220
|
Product Details – FC-0220
- Max Flow (lpm)1.5
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)3
- Noise Level (dBA @ 1m.)25
- Weight (kg).8
Features
- Designed for Preferential Oxidation (PROX) use in hydrogen fuel cell systems
- Designed for 24VDC system applications using a PWM pump controller.
- Pumps equipped with thermal overload protection.
- Designed and built for continuous operation
|
FC-1020
|
10
|
12
|
3
|
30
|
.8
|
FC-1020
|
Product Details – FC-1020
- Max Flow (lpm)10
- Max Cont Operating Pressure (kPa)12
- Power Consumption (Watts)3
- Noise Level (dBA @ 1m.)30
- Weight (kg).8
Features
- Designed for Preferential Oxidation (PROX) use in hydrogen fuel cell systems
- Designed for 24VDC system applications using a PWM pump controller.
- Pumps equipped with thermal overload protection.
|
FC-6030
|
40
|
12
|
12
|
42
|
3.2
|
FC-6030
|
Product Details – FC-6030
- Max Flow (lpm)40
- Max Cont Operating Pressure (kPa)12
- Power Consumption (Watts)12
- Noise Level (dBA @ 1m.)42
- Weight (kg)3.2
Features
- Designed for Cathode air delivery in hydrogen fuel cell systems
- Designed for 24VDC system applications using a PWM pump controller.
- Pumps equipped with thermal overload protection
- Designed and built for continuous operation
|
FC-2030G
|
5.5
|
25
|
4
|
33
|
1.42
|
FC-2030G
|
Product Details – FC-2030G
- Max Flow (lpm)5.5
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)4
- Noise Level (dBA @ 1m.)33
- Weight (kg)1.42
Features
- Designed specifically for incoming gas delivery for hydrogen fuel cell systems, including PEM fuel cells and Solid Oxide fuel cells
- Designed for 24VDC system applications using a PWM pump controller.
- Pumps equipped with thermal overload protection.
- Designed and built for continuous operation
|
HP Alarm Units Select a model for full specifications
Select a model for full specifications
|
HP-40A
|
60
|
20
|
38
|
32
|
6.1
|
HP-40A
|
Product Details – HP-40A
- Max Flow (lpm)60
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)38
- Noise Level (dBA @ 1m.)32
- Weight (kg)6.1
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-60A
|
100
|
25
|
51
|
35
|
7.4
|
HP-60A
|
Product Details – HP-60A
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)51
- Noise Level (dBA @ 1m.)35
- Weight (kg)7.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-80A
|
120
|
25
|
71
|
39
|
7.4
|
HP-80A
|
Product Details – HP-80A
- Max Flow (lpm)120
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)71
- Noise Level (dBA @ 1m.)39
- Weight (kg)7.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100A
|
110
|
25
|
100
|
38
|
8.9
|
HP-100A
|
Product Details – HP-100A
- Max Flow (lpm)110
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)38
- Weight (kg)8.9
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100LLA
|
130
|
30
|
75
|
42
|
9.4
|
HP-100LLA
|
Product Details – HP-100LLA
- Max Flow (lpm)130
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)75
- Noise Level (dBA @ 1m.)42
- Weight (kg)9.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-120LLA
|
150
|
30
|
100
|
42
|
9.4
|
HP-120LLA
|
Product Details – HP-120LLA
- Max Flow (lpm)150
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)42
- Weight (kg)9.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-120A
|
150
|
25
|
125
|
40
|
8.9
|
HP-120A
|
Product Details – HP-120A
- Max Flow (lpm)150
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)125
- Noise Level (dBA @ 1m.)40
- Weight (kg)8.9
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-150A
|
200
|
30
|
155
|
47
|
9
|
HP-150A
|
Product Details – HP-150A
- Max Flow (lpm)200
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)155
- Noise Level (dBA @ 1m.)47
- Weight (kg)9
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-200A
|
200
|
30
|
250
|
48
|
9
|
HP-200A
|
Product Details – HP-200A
- Max Flow (lpm)200
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)250
- Noise Level (dBA @ 1m.)48
- Weight (kg)9
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-Series Select a model for full specifications
Select a model for full specifications
|
HP-20
|
32
|
15
|
17
|
32
|
3.2
|
HP-20
|
Product Details – HP-20
- Max Flow (lpm)32
- Max Cont Operating Pressure (kPa)15
- Power Consumption (Watts)17
- Noise Level (dBA @ 1m.)32
- Weight (kg)3.2
Features
- Standard model available only for 120VAC applications.
- Pumps equipped with thermal overload protection.
|
HP-40
|
80
|
20
|
38
|
32
|
5.7
|
HP-40
|
Product Details – HP-40
- Max Flow (lpm)80
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)38
- Noise Level (dBA @ 1m.)32
- Weight (kg)5.7
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-60
|
100
|
25
|
51
|
35
|
7
|
HP-60
|
Product Details – HP-60
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)51
- Noise Level (dBA @ 1m.)35
- Weight (kg)7
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-80
|
120
|
25
|
71
|
36
|
7
|
HP-80
|
Product Details – HP-80
- Max Flow (lpm)120
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)71
- Noise Level (dBA @ 1m.)36
- Weight (kg)7
Features
- Available with low pressure alarms for 120VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Dual port models available with internal flow switching solenoids and programmable timers for aerator/skimmer applications.
- Contact us for custom voltage applications, including 24 – 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100
|
110
|
25
|
100
|
38
|
8.5
|
HP-100
|
Product Details – HP-100
- Max Flow (lpm)110
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)38
- Weight (kg)8.5
Features
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100LL
|
130
|
30
|
75
|
42
|
9
|
HP-100LL
|
Product Details – HP-100LL
- Max Flow (lpm)130
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)75
- Noise Level (dBA @ 1m.)42
- Weight (kg)9
Features
- Available with low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-120
|
150
|
25
|
125
|
40
|
8.5
|
HP-120
|
Product Details – HP-120
- Max Flow (lpm)150
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)125
- Noise Level (dBA @ 1m.)40
- Weight (kg)8.5
Features
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-120LL
|
150
|
30
|
100
|
45
|
9
|
HP-120LL
|
Product Details – HP-120LL
- Max Flow (lpm)150
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)45
- Weight (kg)9
Features
- Available with low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-150
|
200
|
30
|
155
|
47
|
9
|
HP-150
|
Product Details – HP-150
- Max Flow (lpm)200
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)155
- Noise Level (dBA @ 1m.)47
- Weight (kg)9
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-200
|
240
|
30
|
250
|
48
|
9
|
HP-200
|
Product Details – HP-200
- Max Flow (lpm)240
- Max Cont Operating Pressure (kPa)30
- Power Consumption (Watts)250
- Noise Level (dBA @ 1m.)48
- Weight (kg)9
Features
- Available with integral low-pressure alarms for 120VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
KP-Series Select a model for full specifications
Select a model for full specifications
|
KP-4020
|
37
|
27
|
18
|
31
|
3.8
|
KP-4020
|
Product Details – KP-4020
- Max Flow (lpm)37
- Max Cont Operating Pressure (kPa)27
- Power Consumption (Watts)18
- Noise Level (dBA @ 1m.)31
- Weight (kg)3.8
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
KP-5030
|
42
|
33
|
27
|
34
|
3.8
|
KP-5030
|
Product Details – KP-5030
- Max Flow (lpm)42
- Max Cont Operating Pressure (kPa)33
- Power Consumption (Watts)27
- Noise Level (dBA @ 1m.)34
- Weight (kg)3.8
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
KP-6035
|
51
|
38
|
35
|
36
|
3.8
|
KP-6035
|
Product Details – KP-6035
- Max Flow (lpm)51
- Max Cont Operating Pressure (kPa)38
- Power Consumption (Watts)35
- Noise Level (dBA @ 1m.)36
- Weight (kg)3.8
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
NS-Series Select a model for full specifications
Select a model for full specifications
|
NS-30
|
45
|
8
|
12
|
45
|
1.2
|
NS-30
|
Product Details – NS-30
- Max Flow (lpm)45
- Max Cont Operating Pressure (kPa)8
- Power Consumption (Watts)12
- Noise Level (dBA @ 1m.)45
- Weight (kg)1.2
Features
- Quiet and light weight
- Standard UL listed models available for 120 and 230 VAC.
- Pumps equipped with thermal overload protection.
|
VP-Series Select a model for full specifications
Select a model for full specifications
|
VP-4020
|
42
|
26
|
18
|
43
|
1.95
|
VP-4020
|
Product Details – VP-4020
- Max Flow (lpm)42
- Max Cont Operating Pressure (kPa)26
- Power Consumption (Watts)18
- Noise Level (dBA @ 1m.)43
- Weight (kg)1.95
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
VP-5030
|
54
|
32
|
27
|
44
|
1.95
|
VP-5030
|
Product Details – VP-5030
- Max Flow (lpm)54
- Max Cont Operating Pressure (kPa)32
- Power Consumption (Watts)27
- Noise Level (dBA @ 1m.)44
- Weight (kg)1.95
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
VP-6035
|
60
|
38
|
35
|
45
|
1.95
|
VP-6035
|
Product Details – VP-6035
- Max Flow (lpm)60
- Max Cont Operating Pressure (kPa)38
- Power Consumption (Watts)35
- Noise Level (dBA @ 1m.)45
- Weight (kg)1.95
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
VP-7045
|
62
|
25
|
41
|
46
|
1.95
|
VP-7045
|
Product Details – VP-7045
- Max Flow (lpm)62
- Max Cont Operating Pressure (kPa)25
- Power Consumption (Watts)41
- Noise Level (dBA @ 1m.)46
- Weight (kg)1.95
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
WG Series Select a model for full specifications
Select a model for full specifications
|
WG-2
|
70
|
20
|
24
|
40
|
3.45
|
WG-2
|
Product Details – WG-2
- Max Flow (lpm)70
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)24
- Noise Level (dBA @ 1m.)40
- Weight (kg)3.45
Features
- Standard model available only for 120VAC applications
- Equipped with thermal overload protection
|
WG-3
|
90
|
26
|
38
|
45
|
3.45
|
WG-3
|
Product Details – WG-3
- Max Flow (lpm)90
- Max Cont Operating Pressure (kPa)26
- Power Consumption (Watts)38
- Noise Level (dBA @ 1m.)45
- Weight (kg)3.45
Features
- Standard model available only for 120VAC applications
- Equipped with thermal overload protection
|
WG-4
|
100
|
29
|
57
|
45
|
3.45
|
WG-4
|
Product Details – WG-4
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)29
- Power Consumption (Watts)57
- Noise Level (dBA @ 1m.)45
- Weight (kg)3.45
Features
- Standard model available only for 120VAC applications
- Equipped with thermal overload protection
|
XP Alarm Series Select a model for full specifications
Select a model for full specifications
|
XP-40A
|
70
|
20
|
24
|
30
|
4.1
|
XP-40A
|
Product Details – XP-40A
- Max Flow (lpm)70
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)24
- Noise Level (dBA @ 1m.)30
- Weight (kg)4.1
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
XP-60A
|
90
|
23
|
40
|
35
|
4.3
|
XP-60A
|
Product Details – XP-60A
- Max Flow (lpm)90
- Max Cont Operating Pressure (kPa)23
- Power Consumption (Watts)40
- Noise Level (dBA @ 1m.)35
- Weight (kg)4.3
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
XP-80A
|
100
|
27
|
64
|
35
|
4.3
|
XP-80A
|
Product Details – XP-80A
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)27
- Power Consumption (Watts)64
- Noise Level (dBA @ 1m.)35
- Weight (kg)4.3
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
XP Series Select a model for full specifications
Select a model for full specifications
|
XP-40
|
70
|
20
|
24
|
30
|
4.1
|
XP-40
|
Product Details – XP-40
- Max Flow (lpm)70
- Max Cont Operating Pressure (kPa)20
- Power Consumption (Watts)24
- Noise Level (dBA @ 1m.)30
- Weight (kg)4.1
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
XP-60
|
90
|
23
|
40
|
35
|
4.3
|
XP-60
|
Product Details – XP-60
- Max Flow (lpm)90
- Max Cont Operating Pressure (kPa)23
- Power Consumption (Watts)40
- Noise Level (dBA @ 1m.)35
- Weight (kg)4.3
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
XP-80
|
100
|
27
|
64
|
35
|
4.3
|
XP-80
|
Product Details – XP-80
- Max Flow (lpm)100
- Max Cont Operating Pressure (kPa)27
- Power Consumption (Watts)64
- Noise Level (dBA @ 1m.)35
- Weight (kg)4.3
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|