C-Series Select a model for full specifications
Select a model for full specifications
|
C-5BN
|
100.3 |
202.9 |
8.5
|
34
|
.71.5 |
C-5BN
|
Product Details – C-5BN
- Max Flow (lpm)Max Flow (cfm)10 0.3
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)202.9
- Power Consumption (Watts)8.5
- Noise Level (dBA @ 1m.)34
- Weight (kg)Weight (lbs).7 1.5
Features
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including DC system applications using external PWM controllers for modulating pump flow.
|
CD-8
|
170.6 |
202.9 |
8.5
|
34
|
.71.5 |
CD-8
|
Product Details – CD-8
- Max Flow (lpm)Max Flow (cfm)17 0.6
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)202.9
- Power Consumption (Watts)8.5
- Noise Level (dBA @ 1m.)34
- Weight (kg)Weight (lbs).7 1.5
Features
- Our CD-8 is a C-5BN chassis with enhanced internal sealing for applications requiring improved pneumatic isolation from ambient contamination and the pump’s energized components.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including DC system applications using external PWM controllers for modulating pump flow.
|
DUO Series Select a model for full specifications
Select a model for full specifications
|
DUO 60
|
1003.5 |
202.9 |
39
|
35
|
613.2 |
DUO 60
|
Product Details – DUO 60
- Max Flow (lpm)Max Flow (cfm)100 3.5
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)202.9
- Power Consumption (Watts)39
- Noise Level (dBA @ 1m.)35
- Weight (kg)Weight (lbs)6 13.2
Features
- Dual outlet ports with integrated cam-style valves and programmable timer controller to alternate between two aeration processes
- Available with integral low-pressure alarms.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Equipped with thermal overload protection
- Includes pressure tap location for external alarm sensor
|
DUO 80
|
1103.8 |
253.6 |
58
|
35
|
613.2 |
DUO 80
|
Product Details – DUO 80
- Max Flow (lpm)Max Flow (cfm)110 3.8
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)58
- Noise Level (dBA @ 1m.)35
- Weight (kg)Weight (lbs)6 13.2
Features
- Dual outlet ports with integrated cam-style valves and programmable timer controller to alternate between two aeration processes
- Available with integral low-pressure alarms.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Equipped with thermal overload protection
- Includes pressure tap location for external alarm sensor
|
FC Series for Hydrogen Fuel Cells Select a model for full specifications
Select a model for full specifications
|
FC-0220
|
1.50.0 |
202.9 |
3
|
25
|
.81.7 |
FC-0220
|
Product Details – FC-0220
- Max Flow (lpm)Max Flow (cfm)1.5 0.0
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)202.9
- Power Consumption (Watts)3
- Noise Level (dBA @ 1m.)25
- Weight (kg)Weight (lbs).8 1.7
Features
- Designed for Preferential Oxidation (PROX) use in hydrogen fuel cell systems
- Designed for 24VDC system applications using a PWM pump controller.
- Pumps equipped with thermal overload protection.
- Designed and built for continuous operation
|
FC-1020
|
100.3 |
121.7 |
3
|
30
|
.81.7 |
FC-1020
|
Product Details – FC-1020
- Max Flow (lpm)Max Flow (cfm)10 0.3
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)121.7
- Power Consumption (Watts)3
- Noise Level (dBA @ 1m.)30
- Weight (kg)Weight (lbs).8 1.7
Features
- Designed for Preferential Oxidation (PROX) use in hydrogen fuel cell systems
- Designed for 24VDC system applications using a PWM pump controller.
- Pumps equipped with thermal overload protection.
|
FC-6030
|
401.4 |
121.7 |
12
|
42
|
3.27.0 |
FC-6030
|
Product Details – FC-6030
- Max Flow (lpm)Max Flow (cfm)40 1.4
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)121.7
- Power Consumption (Watts)12
- Noise Level (dBA @ 1m.)42
- Weight (kg)Weight (lbs)3.2 7.0
Features
- Designed for Cathode air delivery in hydrogen fuel cell systems
- Designed for 24VDC system applications using a PWM pump controller.
- Pumps equipped with thermal overload protection
- Designed and built for continuous operation
|
FC-2030G
|
5.50.1 |
253.6 |
4
|
33
|
1.423.1 |
FC-2030G
|
Product Details – FC-2030G
- Max Flow (lpm)Max Flow (cfm)5.5 0.1
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)4
- Noise Level (dBA @ 1m.)33
- Weight (kg)Weight (lbs)1.42 3.1
Features
- Designed specifically for incoming gas delivery for hydrogen fuel cell systems, including PEM fuel cells and Solid Oxide fuel cells
- Designed for 24VDC system applications using a PWM pump controller.
- Pumps equipped with thermal overload protection.
- Designed and built for continuous operation
|
HP Alarm Units Select a model for full specifications
Select a model for full specifications
|
HP-40A
|
602.1 |
202.9 |
38
|
32
|
6.113.4 |
HP-40A
|
Product Details – HP-40A
- Max Flow (lpm)Max Flow (cfm)60 2.1
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)202.9
- Power Consumption (Watts)38
- Noise Level (dBA @ 1m.)32
- Weight (kg)Weight (lbs)6.1 13.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-60A
|
1003.5 |
253.6 |
51
|
35
|
7.416.2 |
HP-60A
|
Product Details – HP-60A
- Max Flow (lpm)Max Flow (cfm)100 3.5
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)51
- Noise Level (dBA @ 1m.)35
- Weight (kg)Weight (lbs)7.4 16.2
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-80A
|
1204.2 |
253.6 |
71
|
39
|
7.416.2 |
HP-80A
|
Product Details – HP-80A
- Max Flow (lpm)Max Flow (cfm)120 4.2
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)71
- Noise Level (dBA @ 1m.)39
- Weight (kg)Weight (lbs)7.4 16.2
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100A
|
1103.8 |
253.6 |
100
|
38
|
8.919.5 |
HP-100A
|
Product Details – HP-100A
- Max Flow (lpm)Max Flow (cfm)110 3.8
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)38
- Weight (kg)Weight (lbs)8.9 19.5
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100LLA
|
1304.5 |
304.3 |
75
|
42
|
9.420.6 |
HP-100LLA
|
Product Details – HP-100LLA
- Max Flow (lpm)Max Flow (cfm)130 4.5
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)304.3
- Power Consumption (Watts)75
- Noise Level (dBA @ 1m.)42
- Weight (kg)Weight (lbs)9.4 20.6
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-120LLA
|
1505.2 |
304.3 |
100
|
42
|
9.420.6 |
HP-120LLA
|
Product Details – HP-120LLA
- Max Flow (lpm)Max Flow (cfm)150 5.2
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)304.3
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)42
- Weight (kg)Weight (lbs)9.4 20.6
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-120A
|
1505.2 |
253.6 |
125
|
40
|
8.919.5 |
HP-120A
|
Product Details – HP-120A
- Max Flow (lpm)Max Flow (cfm)150 5.2
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)125
- Noise Level (dBA @ 1m.)40
- Weight (kg)Weight (lbs)8.9 19.5
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-150A
|
2007.0 |
304.3 |
155
|
47
|
919.8 |
HP-150A
|
Product Details – HP-150A
- Max Flow (lpm)Max Flow (cfm)200 7.0
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)304.3
- Power Consumption (Watts)155
- Noise Level (dBA @ 1m.)47
- Weight (kg)Weight (lbs)9 19.8
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-200A
|
2007.0 |
304.3 |
250
|
48
|
919.8 |
HP-200A
|
Product Details – HP-200A
- Max Flow (lpm)Max Flow (cfm)200 7.0
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)304.3
- Power Consumption (Watts)250
- Noise Level (dBA @ 1m.)48
- Weight (kg)Weight (lbs)9 19.8
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-Series Select a model for full specifications
Select a model for full specifications
|
HP-20
|
321.1 |
152.1 |
17
|
32
|
3.27.0 |
HP-20
|
Product Details – HP-20
- Max Flow (lpm)Max Flow (cfm)32 1.1
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)152.1
- Power Consumption (Watts)17
- Noise Level (dBA @ 1m.)32
- Weight (kg)Weight (lbs)3.2 7.0
Features
- Standard model available only for 120VAC applications.
- Pumps equipped with thermal overload protection.
|
HP-40
|
802.8 |
202.9 |
38
|
32
|
5.712.5 |
HP-40
|
Product Details – HP-40
- Max Flow (lpm)Max Flow (cfm)80 2.8
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)202.9
- Power Consumption (Watts)38
- Noise Level (dBA @ 1m.)32
- Weight (kg)Weight (lbs)5.7 12.5
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-60
|
1003.5 |
253.6 |
51
|
35
|
715.4 |
HP-60
|
Product Details – HP-60
- Max Flow (lpm)Max Flow (cfm)100 3.5
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)51
- Noise Level (dBA @ 1m.)35
- Weight (kg)Weight (lbs)7 15.4
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-80
|
1204.2 |
253.6 |
71
|
36
|
715.4 |
HP-80
|
Product Details – HP-80
- Max Flow (lpm)Max Flow (cfm)120 4.2
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)71
- Noise Level (dBA @ 1m.)36
- Weight (kg)Weight (lbs)7 15.4
Features
- Available with low pressure alarms for 120VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Dual port models available with internal flow switching solenoids and programmable timers for aerator/skimmer applications.
- Contact us for custom voltage applications, including 24 – 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100
|
1103.8 |
253.6 |
100
|
38
|
8.518.7 |
HP-100
|
Product Details – HP-100
- Max Flow (lpm)Max Flow (cfm)110 3.8
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)38
- Weight (kg)Weight (lbs)8.5 18.7
Features
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-100LL
|
1304.5 |
304.3 |
75
|
42
|
919.8 |
HP-100LL
|
Product Details – HP-100LL
- Max Flow (lpm)Max Flow (cfm)130 4.5
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)304.3
- Power Consumption (Watts)75
- Noise Level (dBA @ 1m.)42
- Weight (kg)Weight (lbs)9 19.8
Features
- Available with low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-120
|
1505.2 |
253.6 |
125
|
40
|
8.518.7 |
HP-120
|
Product Details – HP-120
- Max Flow (lpm)Max Flow (cfm)150 5.2
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)125
- Noise Level (dBA @ 1m.)40
- Weight (kg)Weight (lbs)8.5 18.7
Features
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
|
HP-120LL
|
1505.2 |
304.3 |
100
|
45
|
919.8 |
HP-120LL
|
Product Details – HP-120LL
- Max Flow (lpm)Max Flow (cfm)150 5.2
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)304.3
- Power Consumption (Watts)100
- Noise Level (dBA @ 1m.)45
- Weight (kg)Weight (lbs)9 19.8
Features
- Available with low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-150
|
2007.0 |
304.3 |
155
|
47
|
919.8 |
HP-150
|
Product Details – HP-150
- Max Flow (lpm)Max Flow (cfm)200 7.0
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)304.3
- Power Consumption (Watts)155
- Noise Level (dBA @ 1m.)47
- Weight (kg)Weight (lbs)9 19.8
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
HP-200
|
2408.4 |
304.3 |
250
|
48
|
919.8 |
HP-200
|
Product Details – HP-200
- Max Flow (lpm)Max Flow (cfm)240 8.4
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)304.3
- Power Consumption (Watts)250
- Noise Level (dBA @ 1m.)48
- Weight (kg)Weight (lbs)9 19.8
Features
- Available with integral low-pressure alarms for 120VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
KP-Series Select a model for full specifications
Select a model for full specifications
|
KP-4020
|
371.3 |
273.9 |
18
|
31
|
3.88.3 |
KP-4020
|
Product Details – KP-4020
- Max Flow (lpm)Max Flow (cfm)37 1.3
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)273.9
- Power Consumption (Watts)18
- Noise Level (dBA @ 1m.)31
- Weight (kg)Weight (lbs)3.8 8.3
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
KP-5030
|
421.4 |
334.7 |
27
|
34
|
3.88.3 |
KP-5030
|
Product Details – KP-5030
- Max Flow (lpm)Max Flow (cfm)42 1.4
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)334.7
- Power Consumption (Watts)27
- Noise Level (dBA @ 1m.)34
- Weight (kg)Weight (lbs)3.8 8.3
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
KP-6035
|
511.8 |
385.5 |
35
|
36
|
3.88.3 |
KP-6035
|
Product Details – KP-6035
- Max Flow (lpm)Max Flow (cfm)51 1.8
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)385.5
- Power Consumption (Watts)35
- Noise Level (dBA @ 1m.)36
- Weight (kg)Weight (lbs)3.8 8.3
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
NS-Series Select a model for full specifications
Select a model for full specifications
|
NS-30
|
451.5 |
81.1 |
12
|
45
|
1.22.6 |
NS-30
|
Product Details – NS-30
- Max Flow (lpm)Max Flow (cfm)45 1.5
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)81.1
- Power Consumption (Watts)12
- Noise Level (dBA @ 1m.)45
- Weight (kg)Weight (lbs)1.2 2.6
Features
- Quiet and light weight
- Standard UL listed models available for 120 and 230 VAC.
- Pumps equipped with thermal overload protection.
|
VP-Series Select a model for full specifications
Select a model for full specifications
|
VP-4020
|
421.4 |
263.7 |
18
|
43
|
1.954.2 |
VP-4020
|
Product Details – VP-4020
- Max Flow (lpm)Max Flow (cfm)42 1.4
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)263.7
- Power Consumption (Watts)18
- Noise Level (dBA @ 1m.)43
- Weight (kg)Weight (lbs)1.95 4.2
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
VP-5030
|
541.9 |
324.6 |
27
|
44
|
1.954.2 |
VP-5030
|
Product Details – VP-5030
- Max Flow (lpm)Max Flow (cfm)54 1.9
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)324.6
- Power Consumption (Watts)27
- Noise Level (dBA @ 1m.)44
- Weight (kg)Weight (lbs)1.95 4.2
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
VP-6035
|
602.1 |
385.5 |
35
|
45
|
1.954.2 |
VP-6035
|
Product Details – VP-6035
- Max Flow (lpm)Max Flow (cfm)60 2.1
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)385.5
- Power Consumption (Watts)35
- Noise Level (dBA @ 1m.)45
- Weight (kg)Weight (lbs)1.95 4.2
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
VP-7045
|
622.1 |
253.6 |
41
|
46
|
1.954.2 |
VP-7045
|
Product Details – VP-7045
- Max Flow (lpm)Max Flow (cfm)62 2.1
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)253.6
- Power Consumption (Watts)41
- Noise Level (dBA @ 1m.)46
- Weight (kg)Weight (lbs)1.95 4.2
Features
- Optional port locations for maximum design flexibility.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12-48 VDC system applications using external PWM controllers for modulation pump flow.
|
WG Series Select a model for full specifications
Select a model for full specifications
|
WG-2
|
702.4 |
202.9 |
24
|
40
|
3.457.5 |
WG-2
|
Product Details – WG-2
- Max Flow (lpm)Max Flow (cfm)70 2.4
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)202.9
- Power Consumption (Watts)24
- Noise Level (dBA @ 1m.)40
- Weight (kg)Weight (lbs)3.45 7.5
Features
- Standard model available only for 120VAC applications
- Equipped with thermal overload protection
|
WG-3
|
903.1 |
263.7 |
38
|
45
|
3.457.5 |
WG-3
|
Product Details – WG-3
- Max Flow (lpm)Max Flow (cfm)90 3.1
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)263.7
- Power Consumption (Watts)38
- Noise Level (dBA @ 1m.)45
- Weight (kg)Weight (lbs)3.45 7.5
Features
- Standard model available only for 120VAC applications
- Equipped with thermal overload protection
|
WG-4
|
1003.5 |
294.2 |
57
|
45
|
3.457.5 |
WG-4
|
Product Details – WG-4
- Max Flow (lpm)Max Flow (cfm)100 3.5
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)294.2
- Power Consumption (Watts)57
- Noise Level (dBA @ 1m.)45
- Weight (kg)Weight (lbs)3.45 7.5
Features
- Standard model available only for 120VAC applications
- Equipped with thermal overload protection
|
XP Alarm Series Select a model for full specifications
Select a model for full specifications
|
XP-40A
|
702.4 |
202.9 |
24
|
30
|
4.19.0 |
XP-40A
|
Product Details – XP-40A
- Max Flow (lpm)Max Flow (cfm)70 2.4
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)202.9
- Power Consumption (Watts)24
- Noise Level (dBA @ 1m.)30
- Weight (kg)Weight (lbs)4.1 9.0
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
XP-60A
|
903.1 |
233.3 |
40
|
35
|
4.39.4 |
XP-60A
|
Product Details – XP-60A
- Max Flow (lpm)Max Flow (cfm)90 3.1
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)233.3
- Power Consumption (Watts)40
- Noise Level (dBA @ 1m.)35
- Weight (kg)Weight (lbs)4.3 9.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
XP-80A
|
1003.5 |
273.9 |
64
|
35
|
4.39.4 |
XP-80A
|
Product Details – XP-80A
- Max Flow (lpm)Max Flow (cfm)100 3.5
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)273.9
- Power Consumption (Watts)64
- Noise Level (dBA @ 1m.)35
- Weight (kg)Weight (lbs)4.3 9.4
Features
- Integral low-pressure alarm
- Standard UL approved 120 VAC models
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 12 to 48 VDC system applications using external PWM controllers for modulating pump flow.
|
XP Series Select a model for full specifications
Select a model for full specifications
|
XP-40
|
702.4 |
202.9 |
24
|
30
|
4.19.0 |
XP-40
|
Product Details – XP-40
- Max Flow (lpm)Max Flow (cfm)70 2.4
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)202.9
- Power Consumption (Watts)24
- Noise Level (dBA @ 1m.)30
- Weight (kg)Weight (lbs)4.1 9.0
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
XP-60
|
903.1 |
233.3 |
40
|
35
|
4.39.4 |
XP-60
|
Product Details – XP-60
- Max Flow (lpm)Max Flow (cfm)90 3.1
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)233.3
- Power Consumption (Watts)40
- Noise Level (dBA @ 1m.)35
- Weight (kg)Weight (lbs)4.3 9.4
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|
XP-80
|
1003.5 |
273.9 |
64
|
35
|
4.39.4 |
XP-80
|
Product Details – XP-80
- Max Flow (lpm)Max Flow (cfm)100 3.5
- Max Cont Operating Pressure (kPa)Max Cont Operating Pressure (psi)273.9
- Power Consumption (Watts)64
- Noise Level (dBA @ 1m.)35
- Weight (kg)Weight (lbs)4.3 9.4
Features
- Available with integral low-pressure alarms for 120 VAC applications.
- Standard UL approved 120 VAC models, and 230 VAC CE compliant models available.
- Pumps equipped with thermal overload protection.
- Contact us for custom voltage applications, including 24 to 48 VDC system applications using external PWM controllers for modulating pump flow.
- Includes pressure tap location for external alarm sensor
|